Skip to content
Scan a barcode
Scan
Paperback Telecardiology Systems: Signal Conditioning Methods for Cardiac Electric Behavior Book

ISBN: B0CXJJL5MC

ISBN13: 9798224560295

Telecardiology Systems: Signal Conditioning Methods for Cardiac Electric Behavior

Cardio-vascular disease (CVD) is a type of abnormality of faithful heart function. These medical conditions relate to the abnormal health conditions that directly affecting the heart and all its components. Due to the negligently treating, every year, lot of people were maximally suffering by CVDs which is reported by The World health organization 1]- 4]. Among the CVDs, heart failure is caused by the heart inability in pumping required blood for the need of body and sudden heart attacks occur when normal blood circulation ceases because the heart fails contract effectively. Today's biotelemetry is an efficient tool to diagnose about the cardiac abnormalities if the patient is too far to take help from specialist 5]- 6]. The cardiac signal, also called the electrocardiogram (ECG) signal is extracted by a wearable acquisition device and sent through a biotelemetry system to the hospital. The doctor then analyses the signal to take decision for the appropriate action, and the decision is sent to the side where the patient is required for the quick action 7]- 8]. The main considering point here is the ECG signal was interfered with different types of artefacts during the acquisition. Among the artefacts, Power Line Interference (PLI), Baseline Wander (BW), Muscle Artefacts (MA) and Electrode Motion artefacts (EM) are interested as the commonly occurred artefacts. The ECG signal quality is very important in clinical monitoring and diagnosis. These artefacts affect the ECG signal quality. Hence, the need of investigation is high on this issue to extract the high resolution ECG signals from impure recordings which were contaminated with background noise. Therefore in interpretation of easy and accurate ECG, Signal enhancement by filtering is desirable to separate the valid signal components from undesirable artefacts.

Recommended

Format: Paperback

Temporarily Unavailable

We receive fewer than 1 copy every 6 months.

Customer Reviews

0 rating
Copyright © 2025 Thriftbooks.com Terms of Use | Privacy Policy | Do Not Sell/Share My Personal Information | Cookie Policy | Cookie Preferences | Accessibility Statement
ThriftBooks ® and the ThriftBooks ® logo are registered trademarks of Thrift Books Global, LLC
GoDaddy Verified and Secured