Skip to content
Scan a barcode
Scan
Paperback Real-time Filtering of Physiological Tremor for Microsurgery. Physiological Tremor Robotic Compensation Book

ISBN: 3346289893

ISBN13: 9783346289896

Real-time Filtering of Physiological Tremor for Microsurgery. Physiological Tremor Robotic Compensation

Document from the year 2020 in the subject Engineering - Robotics, grade: 2, course: PhD, language: English, abstract: The work conducted in this dissertation focuses on issues that are related to the accurate and real-time separation of physiological tremor components from the sensed motion. This dissertation mainly focused on developing new algorithms and techniques for accurate modeling and prediction of physiological tremor components ( the filtering and modeling system) for the hand-held instruments. The methods developed in the course of this dissertation were validated with the physiological tremor database collected from micro-surgeons and novice subjects. Further, the methods were experimentally validated with the bench tests conducted on hand-held instrument, iTrem. Precision, robustness, dexterity, and intelligence are the design indices for current generation surgical robotics. In microsurgeries, physiological tremor - an intrinsic hand motion with amplitude of 100 m - is a major impediment for surgeons' to perform delicate and fine motor tasks in sub-millimeter space. To augment the required precision and dexterity into normal microsurgical workflow by compensating the tremor in real-time, hand-held robotic instruments are developed. The working principle of a typical handheld instrument involves subsequent execution of three steps 1) sensing its own motion with inertial sensors, 2) filtering the involuntary motion from the sensed motion, and 3) actuate the surgical end-effectors (instrument tip) based on the filtered involuntary motions to compensate the tremor motion. Generally, digital filters are employed to filter out the noise components and subsequently extract the tremor motion from the whole motion. As a result, a time-varying and unknown delay in the range of 20 to 200ms (depends on the variant of the filter) is introduced into the tremor compensation proceedings, which in turn, adversely affects the tremor compensation performance. Ide

Recommended

Format: Paperback

Condition: New

$84.77
Save $14.13!
List Price $98.90
50 Available
Ships within 2-3 days

Related Subjects

Engineering Technology

Customer Reviews

0 rating
Copyright © 2025 Thriftbooks.com Terms of Use | Privacy Policy | Do Not Sell/Share My Personal Information | Cookie Policy | Cookie Preferences | Accessibility Statement
ThriftBooks ® and the ThriftBooks ® logo are registered trademarks of Thrift Books Global, LLC
GoDaddy Verified and Secured