Skip to content
Scan a barcode
Scan
Paperback INDUSTRIAL POWER SYSTEMS PROTECTION: ELECTRICAL ENGINEERING (1) Book

ISBN: 1973316927

ISBN13: 9781973316923

INDUSTRIAL POWER SYSTEMS PROTECTION: ELECTRICAL ENGINEERING (1)

This book will be useful for fresh graduate and post graduate Electrical engineering students & Working professional. This book convers basic Design concept with theory and practical project calculation related to Electrical Protection & it will be a very good handbook for fresh engineer & also experienced professionals. This book contain following Topics: WHY WE NEED PROTECTIVE APPARATUS BASIC FUNCTION OF PROTECTION EQUIPMENTS BASIC PROTECTION EQUIPMENTS POWER SYSTEM PROTECTION FAULTS, TYPES AND EFFECTS VARIOUS TYPES OF DISTRIBUTION SYSTEM TYPES OF VARIOUS FAULT AND THEIR EFFECT ACTIVE FAULTS PASSIVE FAULTS TYPES OF FAULTS ON A THREE-PHASE SYSTEM TRANSIENT AND PERMANENT FAULTS SYMMETRICAL AND ASYMMETRICAL FAULTS CALCULATION OF SHORT-CIRCUIT MVA FUSES HISTORICAL REWIREABLE TYPE CARTRIDGE TYPE FUSE OPERATING CHARACTERISTICS FUSE 'LET THROUGH' ENERGY SELECTION OF FUSE SPECIAL TYPES IS-LIMITER CIRCUIT BREAKERS INTRODUCTION PURPOSE OF CIRCUIT BREAKERS CURRENT UNDER FAULT CONDITION TYPES OF CIRCUIT BREAKERS TYPES OF MECHANISMS COMPARISON OF BREAKER TYPES RELAYS INTRODUCTION ELECTROMECHANICAL IDMTL RELAY CURRENT (PLUG) PICK-UP SETTING TIME MULTIPLIER SETTING BURDEN SETTING OF AN IDMT RELAY FACTORS INFLUENCING CHOICE OF PLUG SETTING MICROPROCESSOR VSELECTRONIC VS TRADITIONAL RELAY BACKGROUND HANDLING OF THE ENERGIZING SIGNAL THE MICROPROCESSOR CIRCUITS THE OUTPUT STAGES THE OUTPUT STAGES UNIVERSAL MICROPROCESSOR OVERCURRENT RELAY ACCURACY OF SETTINGS RESET TIMES STARTING CHARACTERISTICS DUAL SETTING BANKS BREAKER FAIL PROTECTION DIGITAL DISPLAY MEMORIZED FAULT INFORMATION AUXILIARY POWER REQUIREMENTS FLEXIBLE SELECTION OF OUTPUT TYPE TESTING OF STATIC RELAYS TYPE TESTS SELF-SUPERVISION THE FUTURE OF PROTECTION FOR DISTRIBUTION SYSTEMS IED FUNCTIONS OF AN IED SUBSTATION AUTOMATION EXISTING SUBSTATIONS COMMUNICATION CAPABILITY COORDINATION BY TIME GRADING PROTECTION FOR MEDIUM- AND LOW-VOLTAGE NETWORKS INTRODUCTION WHY IDMT? TYPES OF RELAYS NETWORK APPLICATION SENSITIVE EARTH FAULT PROTECTION CONCLUSION LOW-VOLTAGE NETWORKS AIR CIRCUIT BREAKERS MOULDED CASE CIRCUIT BREAKERS CURRENT-LIMITING MCCBS APPLICATION AND SELECTIVE COORDINATION AIR CIRCUIT BREAKER EARTH LEAKAGE PROTECTION RELAY SETTING CALCULATION FOR LV DISTRIBUTION SYSTEM UNIT PROTECTION PROTECTIVE RELAY SYSTEMS MAIN OR UNIT PROTECTIONS BACK-UP PROTECTION DIFFERENTIAL PROTECTION BALANCED CIRCULATING CURRENT SYSTEM BALANCED VOLTAGE SYSTEM BIAS MACHINE DIFFERENTIAL PROTECTION TRANSFORMER DIFFERENTIAL PROTECTION SWITCHGEAR DIFFERENTIAL PROTECTION FEEDER PILOT-WIRE PROTECTION RECOMMENDED UNIT PROTECTION SYSTEMSE TAKEN TO CLEAR FAULTS ADVANTAGES OF UNIT PROTECTION FEEDER PROTECTION: CABLE FEEDERS AND OVERHEAD LINES DISTANCE PROTECTION TRIPPING CHARACTERISTICS APPLICATION ONTO A POWER LINE TRANSFORMER PROTECTION WINDING POLARITY TRANSFORMER CONNECTIONS TRANSFORMER MAGNETIZING CHARACTERISTICS IN-RUSH CURRENT NEUTRAL EARTHING MISMATCH OF CURRENT TRANSFORMERS TYPES OF FAULTS EARTH FAULT DIFFERENTIAL PROTECTION RESTRICTED EARTH FAULT HV OVERCURRENT BUCHHOLZ PROTECTION OVERLOADINGSIMILAR TOPICS FOR SWITCHGEAR, MOTOR, GENERATOR PROTECTIONS

Recommended

Format: Paperback

Condition: Very Good

$10.99
Almost Gone, Only 1 Left!

Customer Reviews

0 rating
Copyright © 2026 Thriftbooks.com Terms of Use | Privacy Policy | Do Not Sell/Share My Personal Information | Cookie Policy | Cookie Preferences | Accessibility Statement
ThriftBooks® and the ThriftBooks® logo are registered trademarks of Thrift Books Global, LLC
GoDaddy Verified and Secured