Skip to content
Scan a barcode
Scan
Paperback Design, simulation, and construction of an illumination unit for non-contact dermatoscopy Book

ISBN: 3668806179

ISBN13: 9783668806177

Design, simulation, and construction of an illumination unit for non-contact dermatoscopy

Master's Thesis from the year 2018 in the subject Physics - Optics, grade: 1,3, University of Hannover (Hannoversches Zentrum f r optische Technologien), language: English, abstract: In this thesis, an existing non-contact dermatoscope will be further developed on the basis of knowledge and experience, and established as a new prototype for dermatoscopy at the Hannover Institute of Optical Technologies (HOT).In this system, the light generated by a white LED is collimated and polarized by a lens system, and generates a homogeneous light spot at a distance of 60cm. By cross polarization, the light reflected directly onto the skin surface can be suppressed, so that only light reflected in deeper skin layers can pass through the analyzer, and contributes to the image information. Due to the difficult handling of the original device, the further developed (advanced) system was compactified and automated, taking into account the basic principle of non-contact dermatoscopy. The illumination unit used in the original non-contact dermatoscope was replaced with a newly constructed reflector in order to improve the brightness, and the homogeneity of the light spot in the target area. These two reflectors were measured with a near field goniophotometer to characterize the illuminance distribution. The conducted tests included the definition of an ideal setup of the lens system, both in practice, and in optical systems simulations by using Zemax. It could be shown that the reflectors improve the illuminance, and generates a homogeneous light spot in the target area, which homogeneously illuminates the image area of the camera. Furthermore, this system has been completely automated by providing automatic focus as well as adjustment of one of the polarizers (analyzer) used. For this purpose, a automatic focus lens was integrated on the existing objective and a mid range infrared distance sensor was installed into the system. By various tests, such as the determination of the reso

Recommended

Format: Paperback

Condition: New

$58.54
Save $6.96!
List Price $65.50
50 Available
Ships within 2-3 days

Customer Reviews

0 rating
Copyright © 2025 Thriftbooks.com Terms of Use | Privacy Policy | Do Not Sell/Share My Personal Information | Cookie Policy | Cookie Preferences | Accessibility Statement
ThriftBooks ® and the ThriftBooks ® logo are registered trademarks of Thrift Books Global, LLC
GoDaddy Verified and Secured