The design-point losses caused by part-span dampers (PSD) were correlated for 21 transonic axial flow fan rotors that had tip speeds varying from 350 to 488 meters per second and design pressure ratios of 1.5 to 2.0. For these rotors a correlation using mean inlet Mach number at the damper location, along with relevant geometric and aerodynamic loading parameters, predicts the variation of total pressure loss coefficient in the region of the damper to a good approximation. Roberts, W. B. Glenn Research Center NASA-TM-X-3542, E-9068 RTOP 505-04